1.Exhibition Sites
Exhibition Area Number Halls
30,000©O 1 No. 1
15,000©O 2 No. 2 and No. 9
7,500©O 6 No. 3, No. 4, No. 5, No. 6, No. 7 and No. 8 
Total exhibition area: 10,5000©O
  • Advanced facilities, large in scale, and flexibly combinable

  • Independent entrances to each exhibition hall, which can be used separately or through combination.

  • The exhibition hall is 126 meters in width, 13 to 28 meters in clear height without any supporting pillar.

  • The floor strong enough for exhibition of large-scale machinery equipment.

  • Natural light is major means of illumination in the exhibition halls. The center has the world¡¯s largest a roof sun light shading system, which is made completely of aerospace materials.

  • Convenient and highly efficient indoor traffic system is made very efficient by the major passage on the 2nd floor, separate entrances to each exhibition hall, and 137 escalators and lifts.

2.Technical Parameters
Item Facility Facts
Lifts
  • 137, including 82 escalators (62 indoors and 20 outdoors), 40 passenger lifts (including 16 fire fighting lifts), 10 sightseeing lifts, 4 hydraulic pressure freight lifts, and one for cafeteria.
  • 48 indoor stairs, and 6 outdoor stairs.
Power Supply to Exhibition Booths Condition Booth power outlet distribution: Duct outlet boxes distributed by every 6m X 10m.Capacity: 25KW/3P¡ª50KW/3P for each outlet box, for the power supply to one 30KW/380V, three 16KW/380V and six 3KW/220V standard electricity sockets for international exhibitions.
Parameters 380V/220V£¨¡À10%£©£¬50Hz£¨¡À1%£©£¨please bring your own power regulatory gears for appliances with incompatible parameters if necessary£©
Lighting in Exhibition Hall Condition Usual lighting and emergency lighting systems are distributed on alternating basis to work with manually adjusted natural lighting dormers
Parameter Light tensity: 300lx¡ª400lx
Hanging Points
  • Hanging rings are provided every 6 meters on the 500mm X 1000mm small beams (in east-west direction) on the ceiling of the exhibition hall.
  • The designed bearing limit of each hanging point is 300Kg (still burden). It is not allowed to use hanging points for the stableness of booth structure
Water & Drainage Water supply point (1 inch in diameter) and draining point (4 inch in diameter) are provided for every 6m X 10m rectangular.
Fire Extinguishing Fire alarm system, smoke discharge system, water cannons, hydrants, portable fire extinguishers
Air-conditioning Condition 16 sets of 108,000m3/h air blaster cabinets are placed beneath the floor
Parameter Temperature can be manipulated between 23 and 27 ¡æ, humidity between 50£¥ and 65£¥, air flow speed between 0.2 and 0.3m per secondFresh air intake: 518,400 m3/h; ventilation: 518,400 m3/h
Compressed air supply Condition Compressed air supply points are distributed on the exhibition floor every 6m X 9m in duct. Pressure at each point is 0.6 Mpa. Compressed air is now only No.2 exhibition hall.
Communication System
  • Duct outlet boxes are distributed for each 6m X 10m area; each box has 8 information ports (voice, data);
  • Domestic/international telephone voice switch capacity (provided by China Telecom): 6,000;
  • China Telecom provides 100M wideband connection;
  • Above floor/underground seamless coverage for wireless walky-talky;
Cable TV Duct outlet boxes are distributed for each area of 6m X 9m. Each box has one cable TV outlet to receive digital and analogical signals from cable TV network.
Broadcasting System Covering the whole exhibition hall.
Emergency Lighting Covering the whole exhibition hall.
Leasing and Other Services Located along major passage of the Comprehensive Service Area on 2nd floor (7.5m)